The dead man alarm system is designed to monitor the ability of the engineer on duty in the engine room. Just before entering the engine room, the engineer on duty should start the adjustable countdown (3 – 27min) of the dead man alarm system for his own safety. In case no reset has been trigged by pushing one of the installed reset units during the pre-defined time the dead man alarm system will start an alarm escalation sequence.
If the dead man alarm system does not detect any reset the alarm will escalate to backup engineer cabin to advise disability of duty personnel. Additionally, the dead man alarm system provides the possibility to call for immediate assistance by pushing one of the reset units for longer than 5 seconds (emergency call).