Signal Light Column

The signal light column is a mini-PLC based stand-alone, shipborne alarm system to indicate visual and audible alarms according to IMO regulations as well as classification society requirements. Controlled by a central unit the signal light column alarm system can also be adapted to your existing alarm and monitoring logic. The sound generation is based on an innovative microprocessor technology and offers multiple acoustic philosophies with up to 120dB(A) sound level.

Available

Different Technologies

Multicore Signal Cable
(230/115VAC/24VDC)

slcBUS Communication

slcBUS Communication

DEVELOPED TO

PROTECT

On one hand visual alarms are indicated by rotating lights or flash lights and on the other hand explicit symbols on triangular indicator are advising the specific alert type. A standard Engine Room Alarm Tower system consists of six, seven or eight alarm indicators (symbols). In case a different amount of alarm indicators is needed, the signal light column alarm system can easily be adapted to your specific requirements.

Data & Features

  • high quality components
  • easy to install
  • shortest delivery time due to modular pre-manufacturing method. Predestined for short-term ship repair projects
  • best price / performance ratio
  • clever commissioning and test features (integrated test mode / lamp test)
  • acoustics delay settings adjustable by user
  • degree of enclosure of all engine room devices: real IP55
  • compact design of control unit
  • only one power supply is needed (230VAC)
  • available system voltages (24VDC, 110VAC, 230VAC)
  • µP controlled dynamic acoustics
  • durable led technology available
  • according to SOLAS/IMO
  • available as standard version (one wire/alarm) or slcBUS version.

STAY CONNECTED

slcBUS

Our slcBUS communication modules allow us to realise almost every project. We did not want to use existing solutions, we wanted to develope our own, made for our requirments . The result is a reliable DNV type approved communication bus system packed with features  

Data & Features

  • 13 signals (equals 10 alarms) over one communication line
  • small cable diameter -> lower cable laying costs
  • Easy zone management: CO2 and Intercom alarms are usually divided into zones throughout the maschinery space. Hang your Hardware first, then select the zone.
  • Smart automatic configuration. System scans for new components by itself. No manual addressing required.
  • Smart connection monitoring. Get instant feedback of system connection status
  • Local lamp test on column, in addition to the global lamp test in the control unit.
  • Option for „Engine room Dead man alarm button“ including illumination feedback
  • Master Module with LCD-Display for system status indication
  •  Save money, errors and time with our sm electrics „slcBUS“ components engineered for the needs of your light signal column system.
  • DNV type approved
 
 

GET FLASHED

MFL-7

By developing our new warning light for the Signaling Column we created some unique advantages, such as displaying 7 different colors in one device.

Data & Features

  • Lower system prices, because only one single light is needed
  • Ability to display 7 different colors and 4 different flash sequences.
  • Low costs for potential spare parts, because of the reduced number of luminaires
  • Better signaling effect thanks to smart lens arrangement and high performance LEDs
  • Lower operating costs result from low power consumption (up to minus 85%) and more flexible system topologies as the overall system power consumption decrease
  • Expanded product life cycle due to advanced LED technology and intelligent control 
  • Different flash sequences allow individual adjustments if there are other devices with a similar flash sequence
  • In contrast to conventional filament bulbs, there is no susceptibility to vibration and shock 
  • Optimized for use in engine room
  • tested according to:
    • DIN EN 60947-1
    • DIN EN 60529
    • IEC 61000-4
    • EN 55011

 

   Our FL-1 (one color flash light) is also available in many colors!

SMART SOUNDER

AGM410

The MED and EN54-3 certified AGM 410.1.8.2 has been designed to generate alarm sound for various marine applications. The main field of application is the ship´s engine room. An alarm sound will be generated by applying 230VAC/115VAC/24VDC to the specific alarm input (CH#1-CH#8) and the enable input. In case more than one alarm sound is activated at the same time, the alarm sound with the higher priority will be generated (CH#1 highest priority, CH#8 lowest priority).

The specific sound characteristic of each alarm input can be modified within a protected service settings menu. The alarm sounds can be chosen from a variety of 64 different maritime sound characteristics. The sounder also includes various smart features, such as a sound soft start for safety at work.

Data & Features

    • low power consumption
    • MED type approved
    • Up to 64 different maritime sound characteristics
    • Smart features (soft start, individual priorities)
    • Degree of enclosure IP56
    • Sound pressure @ 1m -90° – 114dB(A)

Your current system is obsolete?

No problem !

REQUEST PRICE

Contact Information
Below you can attach a specification or other files which may help us to create your offer.

REQUEST PRICE

Your request has been submitted successfully.

We will contact you shortly!