Signal Light Column for engine room
  • Signal Light Column for engine room (LSAS)
    Signal Light Column eingine room alarm tower
  • Engine Order Telegraph & Em´cy Engine Order Telegraph (EOT)
    Engine Order Telegraph & Em´cy Engine Order Telegraph
  • Bridge Alert Management le guardian 3000 with integrated BNWAS (BAM)
    Bridge Alert Management with integrated BNWAS
  • Bridge Navigational Watch Alarm System le guardian 2025 (BNWAS)
    BNWAS le guardian 2025 IEC 62923-1/2 BNWAS
  • Dead Man Alarm for engine room (DMA)
    Dead Man Alarm for engine room
  • common bridge alarm system
    NAS24 Nautical Alarm System
  • Ship telegraph logger
    Ship telegraph logger
  • Ship Alarm Indicator
    Ship Alarm Indicator
  • Cold Store Lock-In Alarm System (LIAS)
    Cold Store Lock-In Alarm System
  • Hospital Call System (HOCS)
    Hospital Call System
  • Rudder Angle Indicator (RAI)
    Rudder Angle Indicator
sm electrics product catalog
Send me the product catalog



* = Mandatory fields


Welcome!

Founded in 2002 sm electrics provides engineering and contract manufacturing services as well as key shipborne MED type approved alarm systems including Bridge Alert Management (BAM), Bridge Navigational Watch Alarm System (BNWAS), Light Signal Columns and further maritime equipment. Its well established sales & service network covering the world’s maritime hotspots complemented with well qualified and motivated staff as the company’s backbone is resulting in sustained success.
 
 
 
 
 
 
 


xxxmade in germany  BSFZ Siegel RGB 1x120   SGS ISO9001
 
light signal column

Signal Light Column - Engine Room Alarm Tower

The signal light column is a mini-PLC based stand-alone, shipborne alarm system to indicate visual and audible alarms according to IMO regulations as well as classification society requirements. Controlled by a central unit the signal light column alarm system can also be adapted to your existing alarm and monitoring logic. The sound generation is based on an innovative microprocessor technology and offers multiple acoustic philosophies with up to 120dB(A) sound level.
 
 
 
 
 
 
 
 
 
 
 
 
 
 
    Wheelmark MEDDNV TA 
 
 
engine order telegraph
Engine Order Telegraph 

sm electrics‘ Engine Order Telegraph (EOT) and Em’cy Engine Order Telegraph Systems (EEOT) formerly designed and distributed by Interschalt respectively Stein Sohn represent the embodiment of safe and sustained µP controlled human machine interface embedded as a basic part into the connected propulsion remote control system.
Downloads: 
download brochure
 
 
 
 
 
 
 
 
 
 
 
 
 
    DNV TA
 
bridge alarm management
Bridge Alert Management System
BAM le guardian
3000 

The certified Bridge Alert Management system with integrated BNWAS – BAM le guardian 3000 is able to handle in addition to the binary alert processing, the newest alert telegram standards as "advanced alert related communication" with ACN, ALC, ALF and ARC according to IEC 61924-2, ALR, TXT, ACK and HBT according to IEC 61162-1 (2) communicated via network protocol EN 61162-450 ("lightweight ethernet") or serial communication (RS-422).
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
    Wheelmark MEDDNV TA
  
bridge navigational watch alarm system
Bridge Navigational Watch Alarm System
BNWAS le guardian 2025

The bridge navigational watch alarm system (BNWAS) monitors bridge activity and detects operator disability that could lead to marine accidents. The system monitors the awareness of the Officer Of the Watch (OOW) and automatically alerts the Master or another qualified person if for any reason the OOW becomes incapable of performing the OOW's duties. This process is subdivided in different alarm stages which primarily try to alert the OOW via visual and audible alerts. The Watch Keeper Alarm System is certified with the recently updated IEC 62923-1/2. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
    Wheelmark MEDDNV TA MER   us coast guard  ccs
 
dead man alarm
Dead Man Alarm (DMA)
DMA le guardian 2025

The dead man alarm system is designed to monitor the ability of the engineer on duty in the engine room. Just before entering the engine room, the engineer on duty should start the adjustable countdown (3 - 27min) of the dead man alarm system for his own safety. In case no reset has been trigged by pushing one of the installed reset units during the pre-defined time the dead man alarm system will start an alarm escalation sequence.
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
    DNV TA
 
nautical alarm system
NAS24 Nautical Alarm System 

  • designed to indicate binary alarms on a common screen especially for marine application. All alarm channels are permanently indicated even though they are not active to give full overview about the monitored states
  • multiple display application is available (network)

 
 
 
 
 
 
 
 
 
 
 
 
    DNV TA
 
ship telegraph logger
Ship telegraph logger

The sm electrics telegraph logger has been designed to replace an outdated bell logger (command printer). The command list of the telegraph logger is able to represent up to 60000 commands, before the list gets refreshed. The telegraph logger will periodically execute an internal backup off the command list which will be exported to an excel sheet. All files are named with the specific timestamp and kept in an internal system folder.
 
ship alarm indicator
Ship Alarm Indicator

Due to our wide range of various triangular light symbols, the ship`s alarm devices are offering a versatile applicability. They can be used for alarm forwarding to additional premises or as alarm indicator for specific alarms (e.g. wind speed alarm on bulk carrier). Our ship's alarm devices are available in different versions (e.g. 1 /2 triangular light symbols, with/without sounder, 24VDC/110VAC/230VAC) even triangular light symbols can be easily customised to your specific needs.
 
cold store lock in alarm
Cold Store Lock-In Alarm System

That highly standardized and modular system is based on a certified 4,3” full graphic touch panel with tight PLC TS35 terminal rail module. Up to six calling points will be monitored and clearly indicated including escalating alarm devices and interface to the higher-ranking BAM/CAM system. The system has been designed with 230VAC main and 24VDC back-up supply.
 
hospital call system
Hospital Call System

That highly standardized and modular system is based on a certified 4,3” full graphic touch panel with tight PLC TS35 terminal rail module. Up to six calling points will be monitored and clearly indicated including escalating alarm devices and interface to the higher-ranking BAM/CAM system. The system has been designed with 230VAC main and 24VDC back-up supply.
 
rudder angle indicator
Rudder Angle Indicator

Picking up and carry on the tradition of HAGENUK, Stein Sohn and Interschalt as rudder angle indication systems provider, deeply established into the market under the brand name „A070“, sm electrics is covering all required equipment. Rock solid transmitter technology as well as diversified indicator family are available as spare part requests just as well as full system replacements.